You are using the ETMoses “beta” application. This is where new features may be tested prior to their full release, however stability cannot be assured and old LESes may cease to work without warning. You may prefer to use the production version instead.

Paddepoel noord toekomstscenario 1 five types marktmodel aanpassing v1

Calculating your local energy solution…
Large local energy solutions may take up to 30 seconds to display. Please be patient, and don't hit refresh!

Click on a network component to view its load and attached technologies

Last updated about 2 years ago

When clicking an end-node technologies will appear

Name (Profile) Output Capacity [kW] Input Capacity [kW] Storage volume [kWh] Yearly demand [kWh] Units
Household aggregated
edsn_e1a
896.7450593 177
Electric car
ev_availability_profile_3_3.7_kW
3.7 3.7 100.0 32
Residential PV panel
solar_pv_groningen
-1.6 -1.6 111
Battery
5.18 5.18 19.8 41
Buffer water heating
hot_water_bdh_scenario_tool
4.0691 2212.642561 177
Heat pump for hot water (air)
10.0 3.33 177
Buffer space heating
appartement_hoog
2.9065 2899.820136 177
Heat pump for space heating (air)
10.0 2.22 177
Name (Profile) Output Capacity [kW] Input Capacity [kW] Storage volume [kWh] Yearly demand [kWh] Units
Household aggregated
edsn_e1a
541.4418762 108
Electric car
ev_availability_profile_3_3.7_kW
3.7 3.7 100.0 20
Residential PV panel
solar_pv_groningen
-1.6 -1.6 68
Battery
5.18 5.18 19.8 25
Buffer space heating
appartement_hoog
2.9065 1698.87207 108
Households space heater district heating
10.0 10.0 108
Buffer water heating
hot_water_bdh_scenario_tool
4.0691 2212.642561 108
Households water heater district heating
10.0 10.0 108
Name (Profile) Output Capacity [kW] Input Capacity [kW] Storage volume [kWh] Yearly demand [kWh] Units
Household aggregated
edsn_e1a
1345.663696 60
Electric car
ev_availability_profile_3_3.7_kW
3.7 3.7 100.0 11
Residential PV panel
solar_pv_groningen
-1.6 -1.6 38
Battery
5.18 5.18 19.8 14
Buffer space heating
Tussenwoning_Hoog
2.9065 4362.369863 60
Heat pump for space heating (ground)
10.0 2.08 60
Buffer water heating
hot_water_bdh_scenario_tool
4.0691 2212.642561 60
Heat pump for hot water (ground)
10.0 3.33 60
Name (Profile) Output Capacity [kW] Input Capacity [kW] Storage volume [kWh] Yearly demand [kWh] Units
Household aggregated
edsn_e1a
1345.663696 89
Electric car
ev_availability_profile_3_3.7_kW
3.7 3.7 100.0 17
Residential PV panel
solar_pv_groningen
-1.6 -1.6 56
Battery
5.18 5.18 19.8 21
Buffer water heating
hot_water_bdh_scenario_tool
4.0691 2212.642561 89
Heat pump for hot water (air)
10.0 3.33 89
Buffer space heating
Tussenwoning_Hoog
2.9065 4362.369863 89
Heat pump for space heating (air)
10.0 2.22 89
Name (Profile) Output Capacity [kW] Input Capacity [kW] Storage volume [kWh] Yearly demand [kWh] Units
Household
anonimous_base_load_10
1460.765235 8
Electric car
ev_availability_profile_3_3.7_kW
3.7 3.7 100.0 1
Residential PV panel
solar_pv_groningen
-1.6 -1.6 5
Battery
5.18 5.18 19.8 8
Buffer space heating
Twee_onder_een_kap_hoog
2.9065 4817.496931 8
Heat pump for space heating (ground)
10.0 2.08 8
Buffer water heating
hot_water_bdh_scenario_tool
4.0691 2212.642561 8
Heat pump for hot water (ground)
10.0 3.33 8
Wait
Created by Dorine van der Vlies on November 16, 2016 10:15 National scenario Local scenario 5 customer market model including heat network