You are using the ETMoses “beta” application. This is where new features may be tested prior to their full release, however stability cannot be assured and old LESes may cease to work without warning. You may prefer to use the production version instead.

test neighborhood battery take 2

Calculating your local energy solution…
Large local energy solutions may take up to 30 seconds to display. Please be patient, and don't hit refresh!

Click on a network component to view its load and attached technologies

Last updated over 2 years ago

When clicking an end-node technologies will appear

Name (Profile) Output Capacity [kW] Input Capacity [kW] Storage volume [kWh] Yearly demand [kWh] Units
Neighbourhood battery
10.0 10.0 100.0 1
Name (Profile) Output Capacity [kW] Input Capacity [kW] Storage volume [kWh] Yearly demand [kWh] Units
Buffer space heating
appartement_hoog
10.0 10.0 2.9065 8469.54 650
Heat pump for space heating (air)
10.0 2.22 650
Buffer space heating
appartement_hoog
10.0 10.0 2.9065 8469.54 650
Heat pump for space heating (ground)
10.0 2.08 650
Buffer space heating
appartement_hoog
10.0 10.0 2.9065 8469.54 124
Households space heater network gas
27.5 27.5 124
Buffer space heating
appartement_hoog
10.0 10.0 2.9065 8469.54 2686
Households space heater combined network gas
20.62 20.62 2686
Buffer space heating
appartement_hoog
10.0 10.0 2.9065 8469.54 65
Hybrid heat pump space heating (electricity)
4.9 4.9 65
Buffer space heating
appartement_hoog
10.0 10.0 2.9065 8469.54 65
Hybrid heat pump space heating (gas)
15.0 15.0 65
Buffer water heating
dhw_demand_1
10.0 10.0 4.0691 2837.84 650
Heat pump for hot water (air)
10.0 3.33 650
Buffer water heating
dhw_demand_1
10.0 10.0 4.0691 2837.84 650
Heat pump for hot water (ground)
10.0 3.33 650
Household
anonimous_base_load_1
3347.71 3248
Buildings
edsn_e3a
89723.82 157
Residential PV panel
solar_pv_zwolle
-1.5 -1.5 767
Electric car
ev_availability_profile_1_3.7_kw
3.7 3.7 25.0 14
Name (Profile) Output Capacity [kW] Input Capacity [kW] Storage volume [kWh] Yearly demand [kWh] Units
Buffer space heating
appartement_hoog
10.0 10.0 2.9065 8469.54 65
Heat pump for space heating (air)
10.0 2.22 65
Buffer space heating
appartement_hoog
10.0 10.0 2.9065 8469.54 65
Heat pump for space heating (ground)
10.0 2.08 65
Buffer space heating
appartement_hoog
10.0 10.0 2.9065 8469.54 124
Households space heater network gas
27.5 27.5 124
Buffer space heating
appartement_hoog
10.0 10.0 2.9065 8469.54 2685
Households space heater combined network gas
20.62 20.62 2685
Buffer space heating
appartement_hoog
10.0 10.0 2.9065 8469.54 65
Hybrid heat pump space heating (electricity)
4.9 4.9 65
Buffer space heating
appartement_hoog
10.0 10.0 2.9065 8469.54 65
Hybrid heat pump space heating (gas)
15.0 15.0 65
Buffer water heating
dhw_demand_1
10.0 10.0 4.0691 2837.84 65
Heat pump for hot water (air)
10.0 3.33 65
Buffer water heating
dhw_demand_1
10.0 10.0 4.0691 2837.84 65
Heat pump for hot water (ground)
10.0 3.33 65
Household
anonimous_base_load_1
3347.71 3247
Buildings
edsn_e3a
89723.82 157
Residential PV panel
solar_pv_zwolle
-1.5 -1.5 766
Electric car
ev_availability_profile_1_3.7_kw
3.7 3.7 25.0 14
Wait
Created by Jeroen van de Logt on January 15, 2016 07:46 National scenario Local scenario Default Market Model